Type |
CM1024 |
CM2024 |
CM2524 |
Rated charging current |
10A |
20A |
25A |
Rated load current |
10A |
20A |
25A |
Work voltage |
12V;12v/24v auto |
Over load, short circuit protection |
Over load protection action: 1.25times rated load current in 60-sec, 1.5 times rated load current in 5-sec; Short circuit protection action: >=3times rated load current |
No load current |
<=6mA |
Charging circuit voltage drop |
<=0.26V |
Load circuit voltage drop |
<=0.15V |
Over voltage protection |
17V, x2/24V |
Work temperature |
Industry stage: -35?to +55?/DIV> |
Boost charge voltage |
14.6V; x2/24V(keep 10-min) (Only applied when overdischarge appears) |
Direct charge voltage |
14.4V; x2/24V(keep 10-min) |
Float charge voltage |
13.6V; x2/24V(keep working until drop to the point of charge return voltage action) |
Charge return voltage |
13.2V; x2/24V |
Temperature compensation |
-5mv//2V(Boost charge, Direct charge, Float charge, charge return voltage) |
Lower voltage indicate |
12.0V; x2/24V |
Over discharge voltage |
11.1V no load-real-time modified voltage by the discharge rate; X2/24V |
Over discharge return voltage |
12.6V; 2/24V |
Control mode |
PWM charge mode |