[合作] 动力电池26650铁锂电池(IFR26650-4000mAh) |
 |
详细信息 |
|
 |
1、基本特性
No.序号
|
Item
项目
|
General parameter
常规参数
|
Remark
备注
|
1
|
Can Material
壳体材质
|
Ni-plate Steel
镀镍钢壳
|
|
2
|
Nominal capacity
标称容量
|
4000mAh
|
0.5C5A
|
3
|
Minimum capacity
***小容量
|
3950mAh
|
0.5C5A
|
4
|
Nominal voltage
标称电压
|
3.2V
|
|
5
|
Maximum charge voltage充电***高电压
|
3.65V
|
|
6
|
Discharge cut-off voltage放电截止电压
|
2.0V
|
|
7
|
Maximum continuous charge current
***大持续充电电流
|
1 C5A
|
|
8
|
Maximum continuous discharge current
***大持续放电电流
|
3 C5A
|
|
9
|
Internal impedance
内阻
|
<20mΩ
|
Measured at AC1KHz of 50%SOC
半电态下交流1KHz测量
|
10
|
Battery weight
电池重量
|
Approx.87g
约87g
|
|
11
|
Battery diameter (d)
电池直径
|
26.5±0.2mm
|
|
12
|
Battery height (h)
电池高度
|
65.5±0.3mm
|
|
13
|
Standard charge
标准充电
|
Constant Current 0.5C5A,Constant Voltage 3.65V,Cut-off Current 0.05C5A
持续电流0.5C5A,持续电压3.65V,截止电流0.05C5A
|
CC/CV
|
14
|
Rapid charge
快速充电
|
Constant Current 1C5A,Constant Voltage 3.65V,Cut-off Current 0.05C5A
持续电流1C5A,持续电压3.65V,截止电流0.05C5A
|
CC/CV
|
15
|
Standard discharge
标准放电
|
Constant Current 0.5C5A, Cut-off Voltage 2.0V
持续电流0.5C5A,截止电压2.0V
|
CC
|
16
|
Operation temperature
工作温度
|
Charge/充电:0℃~45℃
Discharge/放电:-20℃~60℃
|
At 60±25%RH
|
17
|
Storage temperature
储存温度
|
Less than 3 months:-20~45℃
Less than 1 year:-20~25℃
小于3个月:-20~45℃
小于1年:-20~25℃
|
At 60±25%RH
|
2.电性能
No.序号
|
Test Item
检测项目
|
Test Method
测试方法
|
Test Standard
检测标准
|
1
|
Normal temperature discharge performance
常温放电性能
|
Standard charge, then rest for 10min and discharge at 0.5C5A、1C5A 、2C5A 、3C5A to 2.0V respectively.
电池标准充电后,搁置10min,然后以0.5C5A、1C5A、2C5A、3C5A放电至2.0V。
|
Discharge capacity/Nominal capacity×100%
放电容量/标称容量×100%
0.5C5A≥98.5%
1C5A≥97%
2C5A≥95%
3C5A≥80%
|
2
|
Normal Temperature Storage
常温荷电保持能力
|
Store for 28days after standard charge, then discharge at 0.2C5A to 2.0V measuring residual capacity; Then standard charge/discharge cycle for 3 times to obtain the recoverable capacity.
(the same below).
电池标准充电后,开路放置28天,然后标准放电至2.0V。再以标准充放电测试电池的恢复容量,可循环三次,任一次容量达到标准要求,试验即可停止。
|
Residual capacity≥ Nominal capacity×85%
Recoverable capacity≥ Nominal capacity×92%
剩余容量≥标称容量×85%
恢复容量≥标称容量×92%
|
3
|
Cycle Life
循环寿命
|
After 2000 cycles at standard charge and discharge, the residual discharge capacity is above 80% of initial capacity.
将电池按照标准充放电制度循环1000次,电池残余容量≥70%*初始容量。
|
≥1000 cycles
|
4
|
Storage Characteristics
储存性能
|
Stored for 12 months in room-temperature at 50%SOC.After storage cell shall be conducted standard charge/discharge cycle for 5 times to obtain the recoverable capacity. 电池在50%荷电量条件下室温储存12个月后,以标准充放电循环5次,有一次达到标准要求,试验即可停止。
|
Recoverable capacity≥ Nominal capacity×90%
恢复容量≥标称容量×90%
|
5
|
Discharge temperature Characteristics
放电温度特性
|
Standard charged in normal temperature, stored under the following temperature for 3h, then discharged at constant current of 0.2 C5A to 2.0V.
常温条件下电池标准充电后,电池在放电温度环境中放置3h,然后测试0.2C5A放电容量。
|
Discharge capacity/Nominal capacity×100%
放电容量/标称容量×100%
-10℃ ≥60%
25℃ ≥100%
55℃ ≥95%
|
Remark:Measurements are carried out at normal atmospheric pressure、ambient temperature 25±2℃ and relative humidity of 60±25% without other specified condition. Accuracy of voltmeters and ammeters used in test is equal to or better than the grade 0.5.
注:如没有特殊要求测试应在1标准大气压、环境温度25±2℃、相对湿度60±25%条件下进行,测试中所使用的电压表和电流表的精度等级不低于0.5级。
3.环境适应性
No.序号
|
Test Item
检测项目
|
Test Method
测试方法
|
Standard
检测标准
|
1
|
Temperature Cycle
高低温循环
|
After standard charge, the battery in the temperature box, box temperature adjusted in accordance with table 1, five cycles,observation of 1 h.
a)电池标准充电后b)单体蓄电池放入温度箱中,温度箱温度按照表1进行调节,循环次数5次;c)观察1h;
表1:温度循环实验一个循环的温度和实际
|
温度℃
|
时间增量min
|
累计时间min
|
温度变化率℃/min
|
25
|
0
|
0
|
0
|
-40
|
60
|
60
|
13/12
|
-40
|
90
|
150
|
0
|
25
|
60
|
210
|
13/12
|
85
|
90
|
300
|
2/3
|
85
|
110
|
410
|
0
|
25
|
70
|
480
|
6/7
|
|
No deformation,No fire,No explosion.
电池不变形、不起火、不爆炸
|
2
|
Drop
跌落
|
Battery charging standards, from 1.5 m high free fall to the cement ground, positive and negative terminals of a once. Observation of 1 h
电池标准充电后,由1.5m高度自由跌落到水泥地面上,正负端子各一次。观察1h
|
No fire,No explosion.
不起火、不爆炸
|
3
|
Low pressure
(altitude simulate)
低压性能
(高度模拟)
|
After standard charge, cells are stored under the atmosphere pressure of 11.6KPa for 6 hours.
电池标准充电后,在11.6kPa气压下搁置 6h
|
No leakage,No fire,No explosion.
电池不漏液、不起火、不爆炸
|
4
|
Seawater immersion
海水浸泡
|
After standard charge, The battery immersed in 3.5% Nacl solution(mass fraction, simulated under normal temperature water composition) in 2h.
The depth of the water should be no monomer battery.
a)电池标准充电后
b)将单体蓄电池浸入3.5%Nacl溶液(质量分数,模拟常温下的海水成分)中2h;
c)水深应完全没过单体蓄电池。
|
No fire,No explosion.
电池不漏液、不起火、
|
Remark: All safety and environmental tests should be conducted by the professional under the good safeguard. Otherwise the test possibly causes damage to the test equipment or the operator.
注:如需进行上述试验,均须在良好的安全措施保护下,由专业人员进行。否则可能会对试验设备和人身造成意外伤害! |
 |
|