Model
|
AH06K96
|
AH06K175
|
AH07K750
|
AH20K750
|
AH40K1000
|
Input Characteristics
|
Rated input
|
2 phase + protective earth
|
3 phase + protective earth
|
Maximum input
|
90Vac~26Vac,32A max.
|
285Vac~475Vac,38A 、68Amax.
|
Grid Frequency
|
45Hz~65Hz
|
Power Factor
|
≥0.99 @50%~100% full load output power
|
ITHD
|
≤5%@50%~100% full load output power
|
Output Characteristics
|
Voltage plateau
|
96V
|
175V
|
750V
|
750V
|
1000V
|
Voltage Range
|
20Vdc-128Vdc
|
50Vdc-175Vdc
|
50Vdc-750Vdc
|
200Vdc-750Vdc
|
200Vdc-1000Vdc
|
Current Range
|
0A-60A
|
0A-40A
|
0A-20A
|
0A-50A
|
0A-100A
|
Output Power
|
6kW
|
6kW
|
7kW
|
20kW
|
40kW
|
Efficiency
|
>94%
|
Cable and connector
|
CCS2+3m
|
Voltage stabilized accuracy
|
≤±0.5%
|
Current stabilized accuracy
|
≤±1%
|
Voltage Ripple(P-P)
|
≤1%
|
Other Characteristics
|
Dimension
|
199*490*282mm
|
350*500*360mm
|
HMI
|
Display screen, LED Indicator
|
Cooling
|
Fan
|
Weight
|
20kg
|
25kg
|
35kg
|
Protection class
|
IP23
|
Noise
|
≤ 60dB(Class A)
|
Environmental Specifications
|
Operating Temperature
|
-20℃~+75℃, output derating at above 60℃@rated output current, Output derating at above
50℃@Max. output current
|
Storage Temperature
|
-40℃~+75℃
|
Relative Humidity
|
≤95%RH,non-condensing
|
Altitude
|
No derating below 2000m, When the altitude is above 2000 m, the operating temperature decreases by 1°C for each additional 100 m
|