变频器功率KW
|
制动单元型号
|
制动单元数量
|
电阻配置
|
电阻数量
|
制动转矩(10%ED)
|
0.4
|
DBU-4015
|
1
|
70W 750Ω
|
1
|
230
|
0.75
|
DBU-4015
|
1
|
70W 750Ω
|
1
|
130
|
1.5
|
DBU-4015
|
1
|
260W 400Ω
|
1
|
125
|
2.2
|
DBU-4015
|
1
|
260W 250Ω
|
1
|
135
|
3.7
|
DBU-4015
|
1
|
390W 150Ω
|
1
|
135
|
5.5
|
DBU-4015
|
1
|
520W 100Ω
|
1
|
135
|
7.5
|
DBU-4015
|
1
|
780W 75Ω
|
1
|
130
|
11
|
DBU-4015
|
1
|
1040W 50Ω
|
1
|
135
|
15
|
DBU-4015
|
1
|
1560W 40Ω
|
1
|
125
|
18.5
|
DBU-4030
|
1
|
4800W 32Ω
|
1
|
125
|
22
|
DBU-4030
|
1
|
4800W 27.2Ω
|
1
|
125
|
30
|
DBU-4030
|
1
|
6000W 20Ω
|
1
|
125
|
37
|
DBU-4045
|
1
|
9600W 16Ω
|
1
|
125
|
45
|
DBU -4045
|
1
|
9600W 13.6Ω
|
1
|
125
|
55
|
DBU -4030
|
2
|
6000W 20Ω
|
2
|
135
|
75
|
DBU -4045
|
2
|
9600W 13.6Ω
|
2
|
145
|
110
|
DBU -4030
|
3
|
9600W 20Ω
|
3
|
100
|
160
|
DBU -4220
|
1
|
40KW 3.4Ω
|
1
|
140
|
220
|
DBU -4220
|
1
|
60KW 3.2Ω
|
1
|
110
|
300
|
DBU -4220
|
2
|
40KW4.5Ω
|
2
|
110
|
600
|
DBU -4220
|
3
|
60KW3Ω
|
3
|
130
|
ED: 表示制动率在一个制动周期为120s时,制动时间所占比率,如下图可表示为ED=t1/t2=20%.。
ED=20%的配置表适用中等机械设备、20层以下电梯选用
ED=20%,起始斩波电压VDC=760V